DL

DL
Private documents

Pumps of the DL series can be used as vacuum pumps or as compressors of filtered air on stationary of mobile equipment for creating vacuum, for pneumatic transportation or for the suction inside a tank of liquid or solid waste.

This vacuum pump is designed with a new intake manifold. A non-return valve is placed in the suction part of the manifold. The main goal is to reduce the higher temperature reached from all the parts. An equal distribution of the aspirated air is guaranteed by a four-entry points. The air injected does not reduce the volumetric efficiency.

 

Technical sheet
DL
Code Flow Rotation speed Vacuum Continuous vacuum Pressure max abs Power max vacuum Weight HDR File
m3/h l/min cfm rpm rpm % Hg % Hg bar psi kW hp kg lbs
75 483 8050 284 M600 M1000 88 26,5 88 26,5 2 29 12,5 17 175 386 75
95 594 9900 350 M600 M1000 88 26,5 88 26,5 2 29 16 21,7 173 381 95
125 744 12400 440 M600 M1000 88 26,5 88 26,5 2 29 19 25,5 162 357 125
150 900 15000 530 M600 M1000 88 26,5 88 26,5 2 29 24 32 195 430 150
180 1056 17600 621 M600 M1000 88 26,5 88 26,5 2 29 27 36 188 414 180
220 1300 21650 765 M600 - 88 26,5 88 26,5 2 29 34 45,5 215 474 220
250 1500 25000 883 - M1000 88 26,5 88 26,5 2 29 41 55 224 494 250
270 1590 26500 935 M600 - 88 26,5 88 26,5 2 29 43 58 240 529 270
300 1800 30000 1060 - M1000 88 26,5 88 26,5 2 29 51 69 240 529 300